Welcome to Power Asset Condition Engineering Limited, Auckland, New Zealand.
Test and diagnostic instruments for high-voltage and medium-voltage power equipment, supplied into New Zealand and Australia.
Every instrument on this page has been selected on how it behaves in the field rather than on how it reads in a catalogue, and is supported from Auckland by an engineer who has used equipment like it on live plant. If you tell us what you need to measure, we will tell you honestly whether one of these is the right tool — and when it is not.
Where the operating mechanism is accessible, measure it directly. One recorded operation gives contact timing, travel, mean velocity, overtravel and rebound as absolute values judged against published limits — the parameters defined in IEC 62271-100, so the result means the same thing to everyone who reads it. Contact resistance, coil current and minimum operating voltage are measured on the same visit, in the same isolated state.
DB-8000 Series — Circuit Breaker Mechanical Characteristics Analyser
SELECTED & SUPPORTED BY HVPACE
Travel, velocity, timing and contact resistance from a single recorded operation — across SF₆, vacuum, oil and GIS switchgear, in ten configurations.
Fault location is two jobs at two scales. A reflectometer narrows kilometres to a few metres from one end of the circuit; a pinpointer, walked along the route, closes the last stretch to under a metre — which is the number that decides how much road you open. Between them sits a surge generator, because most faults on aged distribution cable hold off normal test voltage and break down only under stress. One sequence, three pieces.
XHGG501E — TDR Cable Fault Locator
SELECTED & SUPPORTED BY HVPACE
Distance to the fault on ranges from 300 m to 65 km — low-voltage pulse where the fault conducts, impulse current or decay where it only breaks down under high voltage.
XHDD503E — Cable Fault Pinpointer
SELECTED & SUPPORTED BY HVPACE
Acousto-magnetic, acoustic, magnetic and step-voltage location on one receiver, positioning a buried cable fault to within 0.1 m — the number that decides how much road you open.
On sealed 11–33 kV ring main units, and on SF₆ and vacuum breakers at 33 kV and above, there is nowhere to clamp a travel transducer — so the conventional mechanical characteristics test is not available. An accelerometer on the enclosure records the same sequence from outside: latch release, contact impact, damper action, settling. Compared against the same breaker's own earlier record, a binding linkage or a spring losing energy shows up as a change in that signature. An acoustic camera covers the other half from a distance — discharge, leaks and looseness radiating into the air, placed on the live camera image.
PACE-DSA Series — Multichannel Dynamic Signal Acquisition Unit
SELECTED & SUPPORTED BY HVPACE
Four or eight IEPE channels quiet enough to record what a transformer core, a tap changer or a breaker mechanism is actually doing — with the host interface galvanically isolated from the switchyard, so the recording shows the plant and not the earth loop.
AcouVista — Power Acoustic Camera
SELECTED & SUPPORTED BY HVPACE
More than 135 microphones in a 245 g module that clips to an Android phone over one USB-C cable. Three detection presets — partial discharge at 10–60 kHz, gas leak at 20–45 kHz, mechanical at 0.5–10 kHz — put the source on the live camera image instead of giving you a direction.
→ View product
A cable or a bus that has just been jointed, repaired or extended has to be proved before it is energised — and on extruded insulation DC does not prove it, because a DC test leaves space charge behind and can do more harm than the defect it was looking for. What the standards ask for is AC at power frequency, which means supplying hundreds of kVAr into a load that is almost pure capacitance. No portable transformer will do that.
Series resonance solves it by tuning rather than by brute force. A variable-frequency source drives a reactor in series with the test object, and at resonance the reactive power circulates between the two instead of being imported: the supply only makes up the losses, so a set drawing a few tens of kVA can hold several hundred kVAr on the sample. The same physics protects the object. When something breaks down, the circuit de-tunes instantly and the current collapses, so the fault is registered rather than burnt in.
Power-frequency AC withstand testing of cable, GIS and transformers at up to 520 kV, from a supply that only has to cover the losses. Modular reactors, variable-frequency excitation, and an automatic tune-and-hold sequence that collapses the current the moment the object breaks down.
A distribution arrester is among the cheapest pieces of plant on the pole, and one of the few that decides whether a lightning stroke ends as a flicker or as a burnt transformer. Metal-oxide blocks do that job without a gap: they sit at leakage current until the voltage rises, conduct hard for the few tens of microseconds the surge lasts, then go back to blocking.
The same material does a second, quieter job underground. On single-core cable with cross-bonded or single-point-bonded sheaths the screen is deliberately left open at one end, so it carries an induced standing voltage in normal service and a far larger transient during a through fault or a switching operation. A sheath voltage limiter, fitted in the link box, holds that transient below the jacket withstand and then returns to blocking.
What separates one unit from another is what happens when it finally fails. An arrester with a built-in disconnector drops its earth lead and releases a visible flag, so the feeder stays in service and the crew can see from the ground which pole to climb.
Distribution Surge Arresters
A gapless metal-oxide arrester for distribution systems to 36 kV, in polymer-housed designs rated to 10 kA line discharge. Versions with an integral disconnector and fault indicator drop the earth lead and show a flag when the unit fails, so the feeder stays in service and the failed pole can be found from the ground.
Sheath Voltage Limiters
A metal-oxide limiter in the link box keeps the sheath of a single-core cable electrically open at service voltage and clamps it during a surge. Supplied for single-point, mid-point and cross-bonded arrangements, rated against the induced sheath voltage of the actual circuit — and, where limiters are being replaced, confirmed to fit the link box already in the ground.
→ Browse all products — or tell us what you need to measure and we will point you at it.