Welcome to Power Asset Condition Engineering Limited, Auckland, New Zealand.
Test and diagnostic instruments for high-voltage and medium-voltage power equipment, supplied into New Zealand and Australia.
Every instrument on this page has been selected on how it behaves in the field rather than on how it reads in a catalogue, and is supported from Auckland by an engineer who has used equipment like it on live plant. If you tell us what you need to measure, we will tell you honestly whether one of these is the right tool — and when it is not.
Where the operating mechanism is accessible, measure it directly. One recorded operation gives contact timing, travel, mean velocity, overtravel and rebound as absolute values judged against published limits — the parameters defined in IEC 62271-100, so the result means the same thing to everyone who reads it. Contact resistance, coil current and minimum operating voltage are measured on the same visit, in the same isolated state.
DB-8000 Series — Circuit Breaker Mechanical Characteristics Analyser
SELECTED & SUPPORTED BY HVPACE
Travel, velocity, timing and contact resistance from a single recorded operation — across SF₆, vacuum, oil and GIS switchgear, in ten configurations.
Fault location is two jobs at two scales. A reflectometer narrows kilometres to a few metres from one end of the circuit; a pinpointer, walked along the route, closes the last stretch to under a metre — which is the number that decides how much road you open. Between them sits a surge generator, because most faults on aged distribution cable hold off normal test voltage and break down only under stress. One sequence, three pieces.
XHGG501E — TDR Cable Fault Locator
SELECTED & SUPPORTED BY HVPACE
Distance to the fault on ranges from 300 m to 65 km — low-voltage pulse where the fault conducts, impulse current or decay where it only breaks down under high voltage.
XHDD503E — Cable Fault Pinpointer
SELECTED & SUPPORTED BY HVPACE
Acousto-magnetic, acoustic, magnetic and step-voltage location on one receiver, positioning a buried cable fault to within 0.1 m — the number that decides how much road you open.
On sealed 11–33 kV ring main units, and on SF₆ and vacuum breakers at 33 kV and above, there is nowhere to clamp a travel transducer sometimes— so the conventional mechanical characteristics test is not available. An accelerometer on the enclosure records the same sequence from outside: latch release, contact impact, damper action, settling. Compared against the same breaker's own earlier record, a binding linkage or a spring losing energy shows up as a change in that signature.
PACE-DSA Series — Multichannel Dynamic Signal Acquisition Unit
SELECTED & SUPPORTED BY HVPACE
Four or eight IEPE channels quiet enough to record what a transformer core, a tap changer or a breaker mechanism is actually doing — with the host interface galvanically isolated from the switchyard, so the recording shows the plant and not the earth loop.
→ Browse all products — or tell us what you need to measure and we will point you at it.